Blower Door Test Results

Simply put a blower door is a diagnostic tool used to measure how much air infiltration air leakage occurs in a house.
Blower door test results. If your home is 2000. I used to go in and do the blower door test first then set up and run the two duct leakage tests. The following will help you conduct your. Better consistency and reproducibility occur at higher pressures.
The blower door test. Blower door test results are standardized for an air pressure difference of 50 pa. Here are some things to know. Once he is done with his walk through your auditor will begin the test.
Here is what a reading on the blower door looks like. What does the blower door number mean. These are some reasons for establishing the proper building. A good rule of thumb is that your home should have a blower door number less than or equal to its square footage.
Holtkamp heating a c inc. The test requires a few parameters be set to yield accurate results. Our energy saver 101 infographic explains the importance of a blower door test during a home energy audit. He will systematically move about your home setting up the house for the test.
If you ve done any of this testing you know that it takes much longer to set up for the duct leakage testing. A blower door test is a machine used to calculate airflow between the interior and exterior of a structure measure the airtightness of buildings and identify spots where air is leaking through a building envelope. This test ensures a certain level of energy performance and is often used when a project team is aiming for a performance based. It s a linear scale so 2000 is twice as bad as 1000.
During this test a calibrated fan is installed in an otherwise sealed door or window while all the other openings to the exterior are closed. Don t do the blower door test first. Jason payne taught me this one several years ago and it makes perfect sense. Air flow at 50 pascals is the preferred value for blower door testing the amount of airflow measured in cubic feet per minute cfm for a.
Blower door test results can determine the airtightness of the building and can be presented in a number of different formats. Higher numbers are worse. The auditor will set up his blower door in an outer door facing outward to depressurize your home in most cases. Cfm50 is the airflow measured in cubic feet per minute from the blower door fan needed to create a change in building pressure of 50 pascals.
A blower door test is used on buildings in order to quantify the amount of air leakage through its enclosure. Professional energy auditors use blower door tests to help determine a home s airtightness. Blower door tests are performed by trained and certified energy auditors but a homeowner can conduct a mini test to help pinpoint leaky areas of the home.